Goyen CA15T Screw Pulse Jet Valves


Detailed Product Description
Power:PneumaticValve Body Material:Aluminium (diecast)
Pressure:30-860KPATemperature:Normal Temperature
Voltage:AC220V AC110V DC12V DC24V
High Light:G1/2 Inch Pulse Jet Valves, Screw Pulse Jet Valves, Goyen Ca15t

GOYEN CA15T SCREW TYPE Solenoid valve G1/2INCH Right angle pulse dust collector

1.Description

High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or Viton (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details.
2.Operation
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick – integral pilots
. EMC (89/336/CE) – integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.

8. Test fire and listen for proper actuation and crisp pulse noise.

Pressure Range: 30(5)-860(125) kPA(Psi)

Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) Viton Seals: -29°C (-20.2°F) to 232°C (449.6°F)

3.Weights:

SizeIntegral Pilot (CA) Kg (lbs)Remote Pilot (RCA) Kg (lbs)SizeIntegral Pilot (CA) Kg (lbs)Remote Pilot (RCA) Kg (lbs)
10NA0.06 (0.14)451.50(3.30)1.28(2.83)
200.60(1.31)0.38 (0.83)502.89(6.38)2.68(5.92)
250.73(1.61)0.51 (1.13)623.31 (7.30)3.09(6.82)
351.04(2.28)0.83 (1.83)764.77(10.52)4.56(10.04)

Maintenance Kits

ModelNitrileVitonLow Temperature -60°C (-76°F) Min.Includes
RCA10TK1001K1002NADiaphragm kits include main and secondary diaphragms (where required) and all springs.These kits are for discontinued valves. o-ring, armature assembly, armature spring, ferrule
CA/RCA20TK2000K2007NA
CA/RCA25TK2501K2503K2504
CA/RCA32T*K2500NA
CA/RCA35TK3500K3501K3502
CA/RCA40T*K4000NA
CA/RCA45TK4502K4503K4522
CA/RCA50/62TK5004K5000NA
CA/RCA76TK7600K7601NA
Pilot repair kitK0380K0384NA

4.Product Characteristics and Performance:

Item CodeNom. SizemmPort Size inchNumber of diaphragmsKvFlow Cv
CA/RCA-10T10103/812.52.9
CA/RCA-20T20203/411214
CA/RCA-25T2525112023
CA/RCA-35T35401.513642
CA/RCA-45T45401.524451
CA/RCA-50T5050227688
CA/RCA-62T62622.5291106
CA/RCA-76T767632144167

5.Dimension(mm and inch):

Goyen CA15T Screw