G353A049 ASCO 2.5″ Pulse jet valve


  • G353A049
  • ASCO
  • 0097
  • Aluminium
  • 0.35~0.85 MPa
  • -10~70 ℃
  • C113686
  • NBR
  • 2.5 inch

1. Product Name: G353A049 ASCO 2.5″ Air control Remote pilot Pulse jet valve Double diaphragm valve

2. Specificaton

pipe sizeorifice sizeflow coefficient Kvoperating pressure differential (bar)catalogue numberOPTION FPM
mln.max. (PS)
air
(mm)(m3/h)(l/min)-/=standardATEX II2G/D
G – Threaded pipe connection
1 1/252467680,358,5G353A046G353A046 GDV
2667712900,358,5G353A048G353A048 GDV
2 1/2669215400,358,5G353A049G353A049 GDV
37617028331,06,0G353-058G353-058 GD⑴V

3. General
Differential pressure (PS) 0,35 – 8,5 bar [1 bar = 100kPa]
Ambient temperature range -40/-20 to +85°C (TPE/CR)

4. Construction
Body: Aluminium
Spring: Stainless steel
Diaphragm: TPE (thermoplastic polyester elastomer) or
CR (chloroprene)

5. Features
1. The diaphragm pulse valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to provide reliable and economical operation
2. The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust collector service applications
3. Integral compression fittings for fast, easy, secure installation
4. Valves can be supplied according to ATEX Directive 94/9/EC for non-electrical equipment by using suffix GD
5. The components satisfy all relevant EC directives

catalogue numberABCDEFGHweight
G353A04630G 1/8″71130136G 3/8″901201.10
G353A04830G 1/4″95168165G 3/4″1211662.60
G353A04930G 1/4″95168165G 3/4″1211662.30
7. Installation
1. The valves can be mounted in any position without affecting operation
2. Threaded pipe connection is: G = G (ISO 228/1) or compression fittings
3. When connecting piping or tubing to the G1/8 connection in the valve bonnet, the remote ASCO pilot valve should be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meter or less have little effect on the pulse response. Installations with over 3 meter of tubing must be tested under actual operating conditions. Tubing with Φ 6 mm O.D. is recommended for all installations
4. For compression fitting types tightness is achieved by the compressed gasket on the blow tube
5. Other pipe threads are available on request
6. Installation/maintenance instructions are included with each valve

7. Spare parts kit and replacement coils are available

8. OPTIONS
1. Valves can also be supplied with FPM (fluorelastomer) diaphragms and seal materials. Use the appropriate optional suffix ‘V’ for identification
2. Sequential controller for pilot solenoid valves
3. Pilot boxes containing 2 to 12 pilot solenoid valves
4. Pilot solenoid valves can be equipped with explosionproof solenoids for hazardous locations according to “ATEX” and national standards