Pulse Jet Valves Diaphragm Kits| ASCO Diaphragm Kit| GOYEN Diaphragm Kit| MECAIR Diaphragm Kit| AUTEL Diaphragm Kit| TAEHA Diaphragm Kit| Watson Kit| Pump Diaphragm kits | Diaphragm displacements

Autel AE1475G225 Pulse Jet Valves

Detailed Product Description
Model: AE1475G225 Nut: Diecast Aluminum
Ferrule: 304SS Armature: 430FR SS
Diaphragm And Seals: PTFE Spring: 304SS
Screws: 302SS Outlet Pipe: Schedule 40 Wrought Steel Zinc Passivated
High Light: AE1475G225, G3 Pulse Jet Valves, Integrated Pulse Jet Valves

Autel AE1475G225 High Performance Integrated valve G3″ Tank valve

Dust collector applications , in particular for reverse pulse jet filter cleaning including bag filters , ceramic filters , and sintered metal fibre filters.

General Description

In the high efficiency series we can include the range of flat surface valves. These valves, used for cleaning filter elements in air filtration systems, are specifically designed for flat surfaces like square header tanks and flanged tank. Like traditional model, with threaded and coupling connection, the activating can be:
Integrated the pilot is placed on the valve and the excitation (electric) is made by a coil.
Remote: the pilot is remote and the excitation is pneumatic. The connection between pilot and valve is made by a simple pneumatic tube.
All That is achieved from a deep studying of internal geometrical characteristics and from a technological research on diaphragm. This guarantees rapid opening-closing cycles and a working for over a million of shots.

Installation

1.  Autel Pulse Jet Valves AE1475G225 valves are installed through the tank, refer to the appropriate template listed above.

2.  To avoid any potential operational problems it is preferable that the valves are not mounted underneath the tank where condensation may collect. All o-rings should be coated with a silicone based lubricant or similar.

3.  Dresser nut seals where used are a pressure seal only, not a structural component. Do not rely on dresser seals to retain either the tanks or blowtubes. Tanks and blowtubes must be independently restrained.

4.  Tighten dresser nuts to 20Nm (15 ftlbs) max.

5.  Tighten pipe outlets to 20 Nm (15 ftlbs).

6.  Connect to Goyen pilot valve, if remotely actuated.

7. Ensure compressed air supply is dry and free from oil and dirt.

8. Check all cleaning system components are secure before applying pressure.

9. Apply moderate pressure and check for leaks.

10.Fully pressurise system.

11.Test fire and listen for proper actuation and crisp pulse noises.

Construction
Body Aluminum (Diecast)
Washer SS 304
Armature SS 430FR
Core and Plugnut Stainless steel
Core Spring SS 304
Sealing & disc NBR(nitrile/buna-n)
Screws SS302
Diaphragm PA-6(Standard), Viton
Connector Pg9 IP65
Voltage 230-150-24 V / 50-60 HZ AC
24 V DC
Working Temperature -20 to +85℃ Nitrile seals -29 to +232℃ Viton seals
Power Absorption 17 VA AC / 17 W DC
Conn.Insulation class C-VDE 0110
Connector specification Din 43650 – IS0 4400
Max Pressure 8 Bar
Recommended on time range 50-500ms
Recommended time between pulses 1 minute or Less

 

 