Pulse Jet Valves Diaphragm Kits| ASCO Diaphragm Kit| GOYEN Diaphragm Kit| MECAIR Diaphragm Kit| AUTEL Diaphragm Kit| TAEHA Diaphragm Kit| Watson Kit| Pump Diaphragm kits | Diaphragm displacements

Goyen CA15T Screw Pulse Jet Valves

Goyen-CA15T-Screw-Pulse-Jet-Valves.jpg
Detailed Product Description
Power: Pneumatic Valve Body Material: Aluminium (diecast)
Pressure: 30-860KPA Temperature: Normal Temperature
Voltage: AC220V AC110V DC12V DC24V
High Light: G1/2 Inch Pulse Jet Valves, Screw Pulse Jet Valves, Goyen Ca15t

GOYEN CA15T SCREW TYPE Solenoid valve G1/2INCH Right angle pulse dust collector

1.Description

High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or Viton (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Seat: PA-6 (standard), Viton coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details.
2.Operation
Recommended on time range: 50-500ms
Recommended time between pulses: 1 minute or greater
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick – integral pilots
. EMC (89/336/CE) – integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.

8. Test fire and listen for proper actuation and crisp pulse noise.

Pressure Range: 30(5)-860(125) kPA(Psi)

Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) Viton Seals: -29°C (-20.2°F) to 232°C (449.6°F)

3.Weights:

Size Integral Pilot (CA) Kg (lbs) Remote Pilot (RCA) Kg (lbs) Size Integral Pilot (CA) Kg (lbs) Remote Pilot (RCA) Kg (lbs)
10 NA 0.06 (0.14) 45 1.50(3.30) 1.28(2.83)
20 0.60(1.31) 0.38 (0.83) 50 2.89(6.38) 2.68(5.92)
25 0.73(1.61) 0.51 (1.13) 62 3.31 (7.30) 3.09(6.82)
35 1.04(2.28) 0.83 (1.83) 76 4.77(10.52) 4.56(10.04)

Maintenance Kits

Model Nitrile Viton Low Temperature -60°C (-76°F) Min. Includes
RCA10T K1001 K1002 NA Diaphragm kits include main and secondary diaphragms (where required) and all springs.These kits are for discontinued valves. o-ring, armature assembly, armature spring, ferrule
CA/RCA20T K2000 K2007 NA
CA/RCA25T K2501 K2503 K2504
CA/RCA32T* K2500 NA
CA/RCA35T K3500 K3501 K3502
CA/RCA40T* K4000 NA
CA/RCA45T K4502 K4503 K4522
CA/RCA50/62T K5004 K5000 NA
CA/RCA76T K7600 K7601 NA
Pilot repair kit K0380 K0384 NA

4.Product Characteristics and Performance:

Item Code Nom. Size mm Port Size inch Number of diaphragms Kv Flow Cv
CA/RCA-10T 10 10 3/8 1 2.5 2.9
CA/RCA-20T 20 20 3/4 1 12 14
CA/RCA-25T 25 25 1 1 20 23
CA/RCA-35T 35 40 1.5 1 36 42
CA/RCA-45T 45 40 1.5 2 44 51
CA/RCA-50T 50 50 2 2 76 88
CA/RCA-62T 62 62 2.5 2 91 106
CA/RCA-76T 76 76 3 2 144 167

5.Dimension(mm and inch):

Exit mobile version