Goyen Diaphragm Valve Repair Kit For Goyen CA20DD RCA20DD010 valves
Place of Origin: | China |
Brand Name: | Goyen or OEM |
Certification: | ISO 9001,CE |
Model Number: | K2008 |
Minimum Order Quantity: | 1 |
---|---|
Price: | Negotiation |
Packaging Details: | carton |
Delivery Time: | 5 working days |
Payment Terms: | T/T , Western Union, Paypal |
Supply Ability: | 2000 pcs/month |
Dresser Seal: | 304SS | Dresser Nut: | Aluminium |
---|---|---|---|
Seal Retainer: | Nitrile | Port Size: | 3/4″ |
Valve Model: | CA20DD Or RCA20DD | ||
High Light: | goyen k2008, goyen diaphragm valve repair kit, k2008 |
1. Product Name: Goyen K2008 CA20DD RCA20DD010 Aluminium Alloy Pulse Jet Dust valve 1 dresser seal 1 dresser nut 1 seal retainer
2. Order code
Ordering Code | Port Size | Orifice | Flow Value | Weight (kg) | ||
G Threaded | mm | Kv | Cv | CA | RCA | |
CA20DD | 3/4″ | 20 | 12 | 14 | 1.25 | |
CA45DD/RCA45DD | 1 1/2″ | 40 | 44 | 51 | 2.30 | 2.15 |
3. Installation
For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure.
1. Prepare supply and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valve to inlet pipes and blowtube to valve, tighten dresser nut.
5. Tanks and pipes must be independently restrained from valve.
6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
7. Apply moderate pressure to system and check for installation leaks.
8. Fully pressurise system.
9. Test fire and listen for proper actuation and crisp pulse noise.
4. Description
High performance diaphragm valve with dresser nut ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.