Pulse Jet Valves Diaphragm Kits| ASCO Diaphragm Kit| GOYEN Diaphragm Kit| MECAIR Diaphragm Kit| AUTEL Diaphragm Kit| TAEHA Diaphragm Kit| Watson Kit| Pump Diaphragm kits | Diaphragm displacements

K2008 Goyen Diaphragm Valve Repair Kit

K2008-Goyen-Diaphragm-Valve-Repair-Kit
Goyen Diaphragm Valve Repair Kit For Goyen CA20DD RCA20DD010 valves
Product Details:
Place of Origin: China
Brand Name: Goyen or OEM
Certification: ISO 9001,CE
Model Number: K2008
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiation
Packaging Details: carton
Delivery Time: 5 working days
Payment Terms: T/T , Western Union, Paypal
Supply Ability: 2000 pcs/month
Detailed Product Description
Dresser Seal: 304SS Dresser Nut: Aluminium
Seal Retainer: Nitrile Port Size: 3/4″
Valve Model: CA20DD Or RCA20DD
High Light: goyen k2008, goyen diaphragm valve repair kit, k2008

1. Product Name: Goyen K2008 CA20DD RCA20DD010 Aluminium Alloy Pulse Jet Dust valve 1 dresser seal 1 dresser nut 1 seal retainer

2. Order code

Ordering Code Port Size Orifice Flow Value Weight (kg)
G Threaded mm Kv Cv CA RCA
CA20DD 3/4″ 20 12 14 1.25
CA45DD/RCA45DD 1 1/2″ 40 44 51 2.30 2.15

3. Installation

For your safety do not pressurise system until all valves and pipes are fully secured. Do not attempt to remove a fitted valve while system is under pressure.
1. Prepare supply and blowtube pipes* to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valve to inlet pipes and blowtube to valve, tighten dresser nut.
5. Tanks and pipes must be independently restrained from valve.
6. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
7. Apply moderate pressure to system and check for installation leaks.
8. Fully pressurise system.
9. Test fire and listen for proper actuation and crisp pulse noise.

4. Description

High performance diaphragm valve with dresser nut ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.